The information on this page was sourced from the Vendors listed website, or publicly available information. It has been confirmed by the Vendors unless indicated by *. As such, the PCSIG bears no responsibility for the accuracy of the content. This table is for guidance only and is not intended to make any recommendations regarding the technologies and vendors featured. Given the complexities of global device regulation, the regulatory status is not provided. Please contact the device vendors to determine whether the regulatory status of a particular technology is suitable for your application.

Please message contact@pcsig.org if you have any amendments to this table.

Please note that viewing of this table works better on desktop devices.

Vendor Brand Names Sampling Location Cut Type Puncture size Website
BD Microtainer® Quikheel™ heel incision 2 products (2.50×1.00 (infant); 1.75×0.85 (preemie)) View
Becton Dickinson Microtainer® Contact-Activated Lancet finger puncture 3 products (1.5 x 2.0mm; 21 G x 1.8mm,;30 G x 1.5mm) View
Cardinal Health* Heel Incision Device heel incision 2 products (1 x 2.5 mm; 0.85 x 1.75mm) View
Cardinal Health* Push Button Activated Safety Lancets finger puncture 7 products (1.8 mm x 18G; 1.8 mm x 21G; 1.4 mm x 25G; 1.6 mm x 28G; 2.0 x 21G; 1.6 mm x 25G; 1.2 mm x 28G) View
Cardinal Health* Adjustable Depth Safety Lancets finger puncture 1.3 mm, 1.8 mm and 2.3 mm in one single, sterile 23G needle View
Cardinal Health* gentleheel® heel incision 4 products (1.4×0.65 mm (micro-preemie); 1.75×0.85 mm preemie); 2.5×1 mm (newborn); 3×2 mm (toddler)) View
Cardinal Health* Contact Activated Safety Lancets finger puncture 7 products (2.0 mm x 21G; 1.8 mm x 25G; 1.5 mm x 30G; 2.0 mm x 21G; 2.0 mm x 23G; 1.8 mm x 28G; 1.5 mm x 30G) View
Cardinal Health* Side Activated Safety Lancets finger puncture 5 products (1.5mm x 30G; 1.8mm x 28G; 1.8mm x 23G; 1.8mm x 18G; 2.0mm x 21G) View
Genteel* Genteel lancing device anywhere on the body puncture not available View
Greiner Bio-One MiniCollect® lancet finger incision 3 products (1.5x1mm, 1.5×1.5mm and 1.5×2.0mm) View
Greiner Bio-One MiniCollect® Lancelino finger puncture 4 products (1.5mm/25g, 1.8mm/21g, 2.25mm/23g and 2.4mm/21g) View
HWTAi* Plastic Lancets finger puncture not specified View
HWTAi* Safety lancet finger puncture 6 products (1.8 x 0.8mm; 1.8 x 0.6mm; 1.8 x 0.45mm; 1.8 x 0.36mm;1.8 x 0.3mm; 2.2 x 0.8mm) View
HWTAi* Lancing device fingertip, palm (at the base of the thumb) or forearm puncture Adjustable – 3 products (Type mini, I & II)10 penetration depths for correct blood volume View
HWTAi* Foot Heel Safety Lancet heel puncture 2 products (0.85 x 1.75mm; 1 x 2.5mm) View
ICU Medical* neoheel™ heel incision 4 products (0.65 x 1.4mm (micro-premie), 0.85 x 1.75mm (preemie), 1.0 x 2.5mm (newborn), 2.0 x 3.0mm (toddler) View
ICU Medical* Safe-T-Lance™ Plus finger incision 6 products (1.5 x 1.6mm; 1.5 x 1.2mm; 28G x 1.6mm; 25G x 1.4mm; 21G x 1.8mm; 18G x 1.8mm) View
IMPROVE* IMPROMINI® Safety Heel Lancet heel incision? 5 products (0.65 x 1.4mm; 0.85 x 1.75mm; 1.0 x 2.5mm; 1.14 x 2.8mm; 2.0 x 3.0mm) View
IMPROVE* IMPROMINI® Safety Lancet finger puncture 6 products (28G x 1.8mm; 26G x 1.8mm; 21G x1.8mm;, 21G x 2.2mm; 21G x 2.8mm; 18G x1.8mm) View
Intrinsyk Medical Devices* Allay™ Toddler heel incision 1.4 x 2.75mm View
LaMeditech* HandyRay-Lite (LMT-1000) finger laser not available View
LaMeditech* HandyRay (LMT-3000) finger laser not available View
LaMeditech* HandyRay-Pro (LMT-5000) finger laser not available View
Laborie* babyLance™ heel incision 3 products (2.2×0.6 mm; 3.0×0.85 mm; 3.0×1.0 mm) View
Medline* Infant Heel Incision Device heel incision 4 products (0.65 x 1.44mm; 1.0 x 2.5mm; 0.85 x 1.75mm; 2.0 x 3.0mm) View
NSP Tech Pte Ltd* SAFETiHEEL™ SH-100 heel incision 4 products (depth 0.65mm; 0.85 mm, 1.0mm; 1.5mm) View
Natus Medical* NeatNick® heel incision 2 products (3.0 x 1.25mm; 2.25 x 1.0mm) View
One-Care* Infant Safety Lancets heel incision 4 products (0.65 x 1.4 mm (micro premie); 0.85 x 1.75mm (premie); 1.0 x 2.5mm (newborn); 2.0 x 3.0mm (toddler) View
Owen Mumford* Unistik® TinyTouch™ heel incision 2 products (1.0 x 2.5mm; 0.85 x 1.75mm) View
ProMedic* HEEL–YELLOW/ORANGE heel incision 2 products (0.85 x 1.75 (pediatric); 1.0 x 2.5mm (neonatal) View
Sarstedt* Safety-lancet finger, ear, heel puncture 5 products (28G x 1.6mm; 21G x 1.8mm; 18G x 1.8mm; 1.2 x 1.5mm; 1.6 x 1.5mm; View
Sarstedt* Safety-Heel® heel incision 2 products (0.85 x 1.75mm (preemie); 1 x 2.5mm (newborn); View
Trans Africa Medicals* Button Activated Safety Blood Lancet finger puncture 3 products (21G x 2.4mm; 23G x 2.4mm; 26G x 1.8mm) View
Trans Africa Medicals* Pressure Activated Safety Blood Lancets type B finger puncture 5 products (21G x 2.4mm; 21G x 2.2mm; 23G x 1.8mm; 26G x 1.8mm; 28G x 1.8mm) View
Trans Africa Medicals* Pressure Activated Safety Blood Lancets type A finger puncture 6 products (21G x 2.4mm; 21G x 2.2mm; 23G x 1.8mm; 26G x 1.8mm; 28G x 1.8mm; 30G x 1.8mm) View
Vitrex Medical* Octaheel Baby and Steriheel Baby heel incision 5 products (0.65 x 1.4 mm (micro-preemie); 0.85 x 1.75mm (preemie); 1.0 x 2.5mm (newborn); 1.14 x 2.8mm (newborn plus); 2 x 3mm (toddler)) View
Werfen* Tenderfoot™ heel incision 4 products (0.65×1.4 mm, 0.85×1.75 mm, 1.0×2.5 mm, 2.0×3.0 mm) View